Skip to main content

AFE-R761 RTC BAT

RTC Battery:

– Typical voltage: 3V

– Normal discharge capacity: 210mAH

HW Pin define:

PinPin Name
1+VDD_RTC
2GND

SW Function

Set the system to the current time then set the RTC.

# date 021710452016 && hwclock -w && date
Wed Feb 17 10:45:00 UTC 2016
Wed Feb 17 10:45:01 UTC 2016

Set one incorrect time, then read RTC to verify.

# date 010100002000 && hwclock -r && date
Sat Jan 1 00:00:00 UTC 2000
2016-02-17 10:49:08.417688+00:00
Sat Jan 1 00:00:00 UTC 2000

Restore the RTC time to system time

# hwclock -s && date
Wed Feb 17 10:46:58 UTC 2016